Exact Measurement & Control (PTY) Ltd Verification and Calibration of Flow Meters Exact Measurement and Control (Pty) Ltd calibrate or verify any type or make on our calibration rig at our Sasolburg facility. Any size from: 10mm to 250 mm Our calibration records contain: K-factor and linearity error at different flow rates At the time of calibration or verification, all instruments used during the performance are traceable to International Measuring Standards Our prices are highly competitive and turn around time within two days or the same day if arranged.
·
·
·
·
Exact Measurement and Control (PTY) Ltd
FLOW CERTIFICATE NUMBER: 05/02/2014  COMPLIANCE AND PERFORMANCE / CALIBRATION/ VERIFICATION  The tested flowmeter checked for correct functionality and accuracy according to Electronic Test Equipment manufactured and supplied by KROHNE (MASTER METER / GS8 SIMILATOR). Cable termination and programming of the tested flowmeter is verified correct within the permitted programming parameter limitations.             Date: 	24th February 2014 Customer: Pinnacle Instruments Verification/ Calibration Date: 24th February 2014 Re- Verification / Calibration Intervals:  12 months Service Technician:  Jaco Kuhn      Master Flowmeter	 							Tested Flow Meter		 Make: 			Krohne							Make: 			Euromag	 Model No:		Optiflux 2000 F						Model No:		MC 608A	 Serial No:		A12010320						Tag No:		n/a	 Size:			DN 25 mm						Serial No:		CAC0617	 GK Value:		GK: 2.7118						Size:			50 mm	 Certificate Number:	DIN55350-18-4.2.2.1 – ISO/IEC 17025:2005		Range:			0-200 l/min	 Uncertainty		0.02%							GK Value:		1.9115	 										New GK Value		1.9940	  Verification / Calibration:  Master Meter		Test Meter		Time Stamp			Range Master  l/m	Range Test  l/m	 4.085546875		4.053710938		2/24/2014 10:35:56 AM	0.00			0.00	 12.11523438		12.12011719		2/24/2014 11:07:11 AM	101.4404297		101.5014648	 12.07128906		12.12501987		2/24/2014 11:08:11 AM	100.8911133		101.562598	 12.1259890		12.13476563		2/24/2014 11:09:11 AM	101.5625978		101.6845703	 12.0859375		12.15429688		2/24/2014 11:10:11 AM	101.0742188		101.9287109	 12.09570313		12.15429688		2/24/2014 11:11:11 AM	101.1962891		101.9287109	 12.15917969		12.17382813		2/24/2014 11:12:11 AM	101.9897461		102.1728516	 12.18847656		12.16894531		2/24/2014 11:13:11 AM	102.355957		102.1118164 	 mA			mA			Deviation			Duration		 12.10595703		12.13232422		-0.325281 %			10:00:00		  Condition: 	1.	Zero done 	2.	The meter is in working / not in working condition. 	3.	Meter within Specification / Not within Specification
Flow Verification
© Exact Measurement and Control (PTY) Ltd. Website designed and hosted by Networx SA ICT Solutions (PTY) Ltd
Exact Measurement & Control (PTY) Ltd Verification and Calibration of Flow Meters Exact Measurement and Control (Pty) Ltd calibrate or verify any type or make on our calibration rig at our Sasolburg facility. Any size from: 10mm to 250 mm Our calibration records contain: K-factor and linearity error at different flow rates At the time of calibration or verification, all instruments used during the performance are traceable to International Measuring Standards Our prices are highly competitive and turn around time within two days or the same day if arranged.
·
·
·
·
Exact Measurement and Control (PTY) Ltd
FLOW CERTIFICATE NUMBER: 05/02/2014  COMPLIANCE AND PERFORMANCE / CALIBRATION/ VERIFICATION  The tested flowmeter checked for correct functionality and accuracy according to Electronic Test Equipment manufactured and supplied by KROHNE (MASTER METER / GS8 SIMILATOR). Cable termination and programming of the tested flowmeter is verified correct within the permitted programming parameter limitations.             Date: 	24th February 2014 Customer: Pinnacle Instruments Verification/ Calibration Date: 24th February 2014 Re- Verification / Calibration Intervals:  12 months Service Technician:  Jaco Kuhn      Master Flowmeter	 							Tested Flow Meter		 Make: 		Krohne				Make: 			Euromag	 Model No:	Optiflux 2000 F			Model No:		MC 608A	 Serial No:	A12010320			Tag No:		n/a	 Size:		DN 25 mm			Serial No:		CAC0617	 GK Value:	GK: 2.7118			Size:			50 mm	 Cert. Number:	DIN55350-18-4.2.2.1 – ISO/IEC 17025:2005	Range:			0-200 l/min	 Uncertainty	0.02%				GK Value:		1.9115	 						New GK Value		1.9940	  Verification / Calibration:  Master Meter	Test Meter	Time Stamp			Range Master  l/m	Range Test  l/m	 4.085546875	4.053710938	2/24/2014 10:35:56 AM	0.00			0.00	 12.11523438	12.12011719	2/24/2014 11:07:11 AM	101.4404297	101.5014648	 12.07128906	12.12501987	2/24/2014 11:08:11 AM	100.8911133	101.562598	 12.1259890	12.13476563	2/24/2014 11:09:11 AM	101.5625978	101.6845703	 12.0859375	12.15429688	2/24/2014 11:10:11 AM	101.0742188	101.9287109	 12.09570313	12.15429688	2/24/2014 11:11:11 AM	101.1962891	101.9287109	 12.15917969	12.17382813	2/24/2014 11:12:11 AM	101.9897461	102.1728516	 12.18847656	12.16894531	2/24/2014 11:13:11 AM	102.355957	102.1118164 	 mA			mA			Deviation			Duration		 12.10595703		12.13232422		-0.325281 %			10:00:00		  Condition: 	1.	Zero done 	2.	The meter is in working / not in working condition. 	3.	Meter within Specification / Not within Specification